Create an appointment to start making the first steps to being compliant
Become compliantCreate an appointment to start making the first steps to being compliant
Get compliantUnderstanding the proposed legislation, remediation deadlines and responsibilities for building owners, landlords, developers and residents.
*Information reviewed 3 November 2026. The Building Safety (Remediation of Unsafe Cladding etc) Bill remains subject to parliamentary approval and amendment. This guidance is general information and does not constitute legal advice.
For further information on Cladding Remediation support & services
Speak to a Building Safety Expert
Plan, manage, and monitor design work during the pre-construction phase through the construction period to ensure external wall remediation strategy complies with Building Regulations from the outset all the way through to completion.
Prepare, coordinate, and manage comprehensive Gateway 2 submissions for higher-risk buildings (HRBs) so you secure Building Safety Regulator (BSR) approval before remediation work begins.
Establish whether your building falls under the Building Safety (Remediation of Unsafe Cladding etc) Bill, map out statutory duties, and align your project programme with the 2029 and 2031 remediation deadlines.
Review existing Fire Risk Assessments of External Walls (FRAEW) and PAS 9980 reports to translate proportionate, risk-based findings into a compliant, buildable remediation scope.
Provide ongoing Building Regulations compliance advice, change control management, and Golden Thread documentation support throughout active facade replacement works.
BSAC can independently review your building's height, external wall assessments, and regulatory status to determine your exact duties under the Building Safety Act and proposed Cladding Remediation Bill.
Get clear, practical guidance to establish your Remediation Compliance Plan, navigate BSR approval routes, and keep your project progressing smoothly.
Navigating cladding remediation requires managing complex technical standards alongside strict statutory deadlines and evolving legislation.
Where remediation constitutes building work to an existing higher-risk building (HRB), the Building Safety Regulator acts as the building control authority—meaning works cannot legally commence until a coordinated Gateway 2 application is submitted and approved. At the same time, responsible entities face increasing enforcement powers and government targets for completing remediation across 11m–18m and 18m+ residential buildings.
Engaging specialist building safety advisers early ensures your design meets Building Regulations, reduces the risk of Gateway 2 rejections or delays, and helps demonstrate clear progress toward statutory compliance.
The Building Safety (Remediation of Unsafe Cladding etc) Bill is proposed legislation intended to accelerate the identification and remediation of unsafe cladding on residential buildings in England. It introduces clearer legal responsibilities, assessment requirements and stronger enforcement powers to ensure unsafe buildings are remediated without unnecessary delays.
The Bill was introduced to Parliament in October 2026 and is currently progressing through the legislative process. There is no confirmed date for Royal Assent, although 2027 is a possible timeframe. Certain proposed duties would take effect two months after Royal Assent.
The proposed legal duty to remediate generally applies to multi-occupied residential buildings in England over 11 metres in height or with at least five storeys, completed before 28 June 2022. This includes qualifying privately owned, social housing, commonhold and resident-managed buildings.
Buildings covered by the Developer Remediation Contract are excluded from this particular duty because equivalent contractual obligations already apply.
The Government's Remediation Acceleration Plan sets targets for buildings with unsafe cladding:
The precise legal obligations and enforcement arrangements will depend on the final legislation
Responsibility generally rests with the party holding the relevant repairing obligations for the building, referred to in the Bill as the responsible entity. This may be a freeholder, landlord, Right to Manage company or resident management company.
Developers may also have separate remediation obligations under existing legislation and developer remediation contracts.
Responsible entities will need to establish whether their buildings fall within the legislation, arrange appropriate external wall fire risk assessments, identify necessary remediation and implement the required works as soon as reasonably practicable.
Where remediation is required, they will also need to prepare a Remediation Compliance Plan, setting out proposed actions and timescales.
The Bill proposes stronger enforcement powers against responsible entities that fail to take appropriate action without reasonable excuse.
Consequences could include financial penalties of up to £500,000 for certain breaches, criminal prosecution and, in serious cases, imprisonment of up to two years.
Enforcement would consider the circumstances of each case, including whether reasonable steps have been taken to progress remediation.
The Government recognises that remediation projects can experience delays due to complex design requirements, contractor availability, supply chains and regulatory processes.
The proposed legislation includes a reasonable excuse defence for certain failures outside the responsible entity's control. However, building owners should be able to demonstrate that appropriate steps have been taken to progress remediation and minimise delays.
Developers with existing remediation obligations must continue to meet those commitments, including those under the Developer Remediation Contract and Responsible Actors Scheme.
The Bill also proposes changes to make it easier for developers and other eligible parties to pursue claims against manufacturers of unsafe construction products where those products have contributed to building safety failures.
Existing Building Safety Act protections restrict the recovery of certain building safety remediation costs from qualifying leaseholders.
The Government has also confirmed that funding is intended to be available for remediation required under the proposed new legal duty, meaning leaseholders should not have to contribute towards those works.
Individual circumstances and eligibility should still be reviewed.
Residents should initially raise their concerns with the building owner or managing agent and request details of the building's external wall assessment, proposed remediation and anticipated programme.
Concerns may also be raised with the relevant regulator. Existing legislation provides routes for eligible parties to seek Remediation Orders, while the Bill proposes additional powers to intervene where responsible parties fail to act.
In many cases, yes. Cladding remediation is frequently undertaken while residential buildings remain occupied.
However, works require careful planning to maintain safe access, fire safety arrangements and resident welfare throughout construction. Temporary restrictions or alternative arrangements may be necessary depending on the scope of works.
A Fire Risk Assessment of External Walls (FRAEW) evaluates the fire risks associated with a building's external wall construction, including cladding, insulation and associated components.
The assessment helps determine whether remediation or other risk mitigation measures are necessary. The Bill proposes mandatory assessment requirements and independent auditing to improve consistency and quality.
PAS 9980 provides a methodology for assessing the fire risk associated with external wall construction on existing multi-storey residential buildings.
It supports proportionate, risk-based assessments rather than assuming that every combustible material automatically requires removal.
The findings can inform the extent of necessary remediation and the development of a suitable remediation strategy.
Where cladding remediation constitutes building work to an existing higher-risk building, Building Safety Regulator approval will generally be required before the relevant work can commence.
This is commonly referred to as Gateway 2 and requires a coordinated submission demonstrating how the proposed works will comply with applicable Building Regulations.
Construction programmes vary considerably depending on building height, façade complexity, access arrangements and the extent of remediation required.
For a typical higher-risk residential tower, an indicative on-site programme may be 12–24 months, with more complex projects taking longer.
Additional time should be allowed for investigations, design development, regulatory approvals, procurement and completion procedures.
Building owners and responsible entities should review their portfolios, establish which buildings may be affected, confirm the status of existing external wall assessments and identify any outstanding remediation requirements.
Early engagement with competent technical advisers, designers and contractors can help establish a realistic remediation strategy, programme and regulatory approval pathway.
Building Safety Act Consult (BSAC) supports clients in navigating the building safety regulatory framework, including higher-risk building remediation projects.
Our services include Building Regulations Principal Designer appointments, Gateway 2 application preparation and coordination, Building Regulations compliance advice, and support with construction-stage regulatory obligations.
We can assist building owners, landlords, developers and project teams in understanding their regulatory requirements and progressing projects through the relevant approval processes.